CBTCL - PN:CH21101-1 DETECTOR TUBES

  • MSDS: CBTCL
  • Manufacturer: NATIONAL DRAEGER INC
  • Product Name: PN:CH21101-1 DETECTOR TUBES
  • National Stock Number: 6665-01-010-7962
Product Identification

Product ID:PN:CH21101-1 DETECTOR TUBES
MSDS Date:02/27/1985
FSC:6665
NIIN:01-010-7962
MSDS Number: CBTCL

Responsible Party
NATIONAL DRAEGER INC
101 TECHNOLOGY DRIVE
PITTSBURGH, PA 15372
US

Emergency Phone: 412-787-8383 OR 412-787-8389

Info Phone: 412-787-8383 OR 412-787-8389

Preparer: EDWARD G. LIGUS

Cage: 53833

Contractor
NATIONAL DRAEGER INC
PITTSBURGH, PA 15372 US

Telephone: 412-787-8383 OR 412-787-8389

Cage: 53833

Ingredients

HERMETICALLY SELAED GLASS TUBE (TYPICALLY 125MMX7MM)


INERT CARRIER MATERIAL (SUCH AS SILICALGEL OR PUMICE)


CHEMICAL(S)/REAGENT

Hazards

LD50 LC50 Mixture:NP
Health Hazards Acute and Chronic:PER LETTER FROM E.G.LIGUS (NAT DRAEGER
INC) TO JOHN B. MILES JR,DIR,DIRECTORATE OF FIELD OPERATIONS(DEPT
OF LABOR,OSHA):"DETECTOR TUBE CONTAINS AN INERT CARRIER MATERIAL
SUCH AS SILICAGEL OR PUMICE WH ICH HAS BEEN IMPREGNATED
W/CHEM(S).AMT OF CHEM/REAGENT REQUIRED FOR 1 TUBE IS IN THE RANGE
OF MICROGRAMS TO (SUPPLEMEN)
Explanation of Carcinogenicity:NP
Effects of Overexposure:NP
Medical Cond Aggravated by Exposure:NP

First Aid

First Aid:NP

Fire Fighting

Flash Point:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:NP
Fire Fighting Procedures:NP
Unusual Fire/Explosion Hazard:NP

Accidental Release

Spill Release Procedures:NP
Neutralizing Agent:NP

Handling

Handling and Storage Precautions:NP
Other Precautions:PER E.G. LIGUS LETTER:DETECTOR TUBES USED IN VAR
INDUSTRIES FOR MONITORING LEVELS OF TOXIC/COMBUST
GAS/VAP.HERMETICALLY SEALED GLASS TUBE,TYP 125MMX7MM CONTAINS INERT
CARRIER MATL SUCH AS SILICAGEL/PU MICE IMPREGNATED W/CHEM(S).(HYG
PRACT)

Exposure Controls

Respiratory Protection:NP
Ventilation:NP
Protective Gloves:NP
Eye Protection:NP
Other Protective Equipment:NP
Work Hygienic Practices:OTHER PREC:AMT OF CHEM/REAGENT REQUIRED FOR 1
TUBE IS IN RANGE OF MICROGRAM TO MILLIGRMAS;MINUTE COMPARE TO
CARRIER AMT"
Supplemental Safety and Health
HEALTH HAZ:MG;MINUTE AMT COMPARED TO AMT OF REAGENT CARRIER.DETECTOR
TUBE MFG ITEM & REQUEST EXEMPTION FROM HAZ COMM FINAL RULE."PER
LETTER FROM J.B. MILES,JR TO E.G. LIGUS:"A DETECTOR TUBE WOULD BE E
XEMPTED FROM REQMTS OF HCS UNDER PARA (B)(5)(IV) AS AN ARTICLE."

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NP
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:NP
Vapor Density:NP
Spec Gravity:NP
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:NP
Appearance and Odor:ARTICLE.
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

NP
Stability Condition to Avoid:NP
Hazardous Decomposition Products:NP

Disposal

Waste Disposal Methods:NP

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.